PARTS & ACCESSORIES
Quick RefeRence Guide
The Beckett AquaSmart is an advanced boiler control designed for use on residential and light commercial
boiler systems. All models include the option of enabling Beckett HeatManager™ dynamic temperature reset
that, when selected, provides up to 20% fuel consumption savings. The control includes a backlit LCD digital
display with touch pad to easily program temperature limits, differentials, and other advanced options. The
AquaSmart also has memory storage of system history for help with diagnostics and troubleshooting.
Temperature Ranges and Differentials
High Limit Setting Range: 100 to 240°F (38 to 116°C)
High Limit Differential Range: 5 to 45°F (3 to 25°C)
Low Limit Setting Range: 100 to 220°F (38 to 104°C)
Low Limit Differential Range: 10 to 45°F (6 to 25°C)
Factory Range Stops available - consult factory
Environmental Ratings
Storage Temperature: -40 to +150°F (-40 to +65°C)
Operating Temperature: -4 to +150°F (-20 to +65°C)
Maximum Sensing Element Temperature: 250°F (121°C)
Relative Humidity: 5 to 85% RH, non-condensing and
non-crystallizing
Technical Specications
Electrical Ratings
Input Voltage: 120 Vac - 50/60 Hz.
Input Current: 0.1 A + B1 + C1 + ZC
MAX Input Current: 20A (Reduce to 15A if optional
power switch is used)
24 Vac Thermostat Anticipator Current: 0.1 Amp.
Burner Current Rating (B1):
7600A (oil): 7.4 A at 120 Vac FLA; 44.4 A inrush LRA.
7600B (gas): 1.25 A at 24 Vac; 30 VA (total load).
Circulator Current Rating (C1): 7.4 A at 120 Vac FLA;
44.4 A inrush LRA.
Zone Control Current Rating (ZC): 7.4 A at 120 Vac
FLA; 44.4 A inrush LRA.
Do Not Use This Control in an Application that is Not Within the Ratings
Listed in This Section. Improper Control Operation May Result.
Electrical Shock, Fire, Explosion and Burn Hazards
This control must be installed, adjusted and put into operation only by a trained, licensed, qualied
professional or service agency in accordance with the National Electric Code ANSI/NFPA 70 (Canada CSA
C22.1) state, local codes and authorities having jurisdiction.
The installer must carefully read and follow the installation and service instructions contained in this pamphlet and in
the owner’s manual. Make them available to the equipment owner, so they can be kept for future reference.
Please refer to the AquaSmart Owners Manual for more detailed instructions and advanced
programming options.
Approvals
Underwriters Laboratories Recognition to UL353, UL1998 for U.S. and Canada
Przeglądanie stron 0
1 2 3 4

Podsumowanie treści

Strona 1 - Quick RefeRence Guide

PARTS & ACCESSORIESQuick RefeRence GuideThe Beckett AquaSmart is an advanced boiler control designed for use on residential and light commercial b

Strona 2 - Basic Programming

Page 2Figure 1 - Getting to know the AquaSmart 7600 Series ControlOEM Installation: When replacing an OEM-installed AquaSmart, consult the applia

Strona 3

Page 3Figure 2 - 7600A/B single-zone connections with or without a tankless coilControl Wiring:1. Set “DHWP OFF” (default, see programming secti

Strona 4 - WARRANTY

Form No. 61757 Rev. 0, Printed in USA 09/09PARTS & ACCESSORIESUSA: P.O. Box 1289 ● Elyria, OH 44036 ● Phone: 800-OIL-BURN (800-645-2876)Canada:

Komentarze do niniejszej Instrukcji

Brak uwag